COBRA EXTRA FLEXIBLE MARINE BOAT WIRING CABLE
DESCRIPTION
Model Number | Size (AWG) | Stranding | Insulation (IN) | Nominal OD (IN) | UL Style | Cable Lenght |
A1016T-01 | 16 | 26 X 30 | 0.032 | 0.123 | TC AWMTEW RED UL1015 | 1.50MM X 330 Feet(99Mtr) |
A1016T-02 | 16 | 26 X 30 | 0.032 | 0.123 | TC AWMTEW BLUE UL1015 | 1.50MM X 330 Feet(99Mtr) |
A1016T-07 | 16 | 26 X 30 | 0.032 | 0.123 | TC AWMTEW BLACK UL1015 | 1.50MM X 330 Feet(99Mtr) |
A1014T-01 | 14 | 41 X 30 | 0.032 | 0.141 | TC AWMTEW RED UL1015 | 2.50MM X 330 Feet(99Mtr) |
A1014T-02 | 14 | 41 X 30 | 0.032 | 0.141 | TC AWMTEW BLUE UL1015 | 2.50MM X 330 Feet(99Mtr) |
A1014T-07 | 14 | 41 X 30 | 0.032 | 0.141 | TC AWMTEW BLACK UL1015 |
• This product was designed to meet the requirements of Underwriters Laboratories. | |
• It can be used as internal wiring of electrical and electronic equipment, internal wiring of • panels and meters, point to point, etc. | |
• Stranding is tin-coated copper for corrosion resistance. |
• Insulation: This product offers a unique flame retardant polyvinyl chloride compound (VW-1), and is moisture, abrasion, acid, diesel fuel, and oil resistant. It is extremely flexible and easy to work with. |
• Stranding: Class K Tinned Copper |
•Standard: UL 1015-1230 | |||||
• Voltage: 600 Volts | |||||
• Temperature: 105°C Dry, 75°C Wet BOAT WIRING CABLE |
FLAT MULTI CONDUCTOR MARINE CABLE (MEETS UL & ABYC STANDARDS)
DESCRIPTION
Model Number | Size (AWG) | Stranding | Insulation (IN) | Nominal OD (IN) | UL Style | Cable Length |
B7W16T-21 | 16 | 26 x 30 | 0.03 | 0.192 x 0.319 | TC WHT RED & BLACK FLAT UL BOAT | 1.50MM x 330 Feet(99Mtr) |
B7W14T-21 | 14 | 41 x 30 | 0.03 | 0.215 x 0.350 | TC WHT RED & BLACK FLAT UL BOAT | 2.50MM x 330 Feet(99Mtr) |
• This specification covers the requirements for flexible multi conductor tinned copper, flame retardant boat cable. |
Cobra boat cable meets or exceeds ABYC, UL, Coast Guard requirements, and is ABS Type approved. Cable |
is rated at 105°C Dry, 75°C Wet (BC-5W2) 600 Volt UL 1426 for AC and DC circuits. |
• Insulation: This product offers a unique flame retardant polyvinyl chloride compound (VW-1), and is moisture, abrasion, acid, diesel |
fuel and oil resistant. It is extremely flexible and easy to work with. |
• Stranding: Class K 30 Gauge Tinned Copper |
• Standard: UL 1426, UL Listed BC-5W2 |
• Voltage: 600 Volts |
• Temperature: 105°C dry, 75°C wet |
SPEAKER WIRE (CLEAR)
DESCRIPTION
14/2 |
• 14/2 19/27 BC / TC Speaker Cord 0.016″ Wall Clear |
• Stranding: 14 19/27 BC LHL / 14 19/27 TC LHL |
• Insulation: PVC |
• Length: 350 FT |
18/2 |
• 18/2 16/30 BC / TC Speaker Cord 0.023″ Wall Clear |
• Stranding: 18 16/30 BC LHL / 18 16/30 TC LHL |
• Insulation: PVC |
• Length: 350 FT |